SURVIVOR™ CT Class 2 Transformers

Now available in high energy efficient models.

Foster’s SURVIVOR™ CT Class 2 transformers add a new dimension to the industry’s most innovative series of Class 2 transformers. Like their namesake, all models in this series meet the stringent requirements for an Inherently Limited Class 2 Power Source. This means that they can be used without additional circuit protection and thanks to their resettable thermal protectors are guarded against damage from accidental overload or short circuit.

The SURVIVOR™ CT adds a 12 V tap to the secondary winding providing the ability to operate 12 or 24 volt controls from a single transformer. For 12 V applications where the load can be split between each half of the secondary winding, a full 100 VA of 12 V power becomes available when using a 100 VA transformer. With a single 12 V output, Class 2 limits are a maximum of 5 A of current or 60 VA.

Foster’s SURVIVOR™ CT is a perfect match for low voltage halogen lighting, DC power supply, motor control, and appliance applications.

Designed for use in HVAC, Appliance, Vending, Battery Charger and other applications requiring a Class 2 Control Transformer. All Designs are Inherently Limited as defined by UL 5085-3 (UL 1585).

  • UL / C-UL Recognized. UL File: E17029
  • UL Recognized Class 130 (B) Insulation System.
  • Breakthrough Short Circuit & Overload Protection.
  • No External Fusing Required.
  • Can Withstand a Direct Short Circuit in Excess of 15 Days!
  • Lowers Warranty Costs, Improves Customer Satisfaction.
  • CE Compliant Designs Available.
SURVIVOR CT
SURVIVOR CT
SURVIVOR CT
ModelInputFrequencyOutputCapacityABCDEF
15299115V50/60 Hz24VCT30VA2 13/163 4/162 3/162 3/16 
16131200/230V60Hz24VCT75VA3 9/1642 8/162 9/16 3/16 
16132460V60Hz24VCT75VA3 9/1642 8/162 9/16 3/16 
16132-50460V50/60Hz24VCT75VA3 9/1642 12/162 9/16 3/16 
16133115/(200)/230V60Hz24VCT75VA3 9/1642 8/162 9/16 3/16 
16133-50115/(200)/230V50/60Hz24VCT75VA3 9/1642 12/162 9/16 3/16 
16134115V60Hz24VCT75VA3 9/1642 8/162 9/16 3/16 
16134-50115V50/60Hz24VCT75VA3 9/1642 12/162 9/16 3/16 
16135200/230V50/60Hz24VCT75VA3 9/1642 12/162 9/16 3/16 
16213115V50/60Hz24VCT100VA2 8/1632 12/162 13/1613/6410/16
16214115/(200)/230V50/60Hz24VCT100VA2 8/1632 12/162 13/1613/6410/16
16215200/230V50/60Hz24VCT100VA2-1/232-3/42-13/1613/645/8
16232115V60Hz24VCT100VA3 9/1642 12/162 9/16 3/16 
16233115/(200)/230V60Hz24VCT100VA3 9/1642 12/162 9/16 3/16 
16234200/230V60Hz24VCT100VA3 9/1642 12/162 9/16 3/16 
Displaying 15 of 15 models

Notes:

  1. All part numbers are UL Recognized, C-UL Component Certified to UL 5085-3 (UL1585) / C.S.A. C22.2, Number 66.1.
  2. 200 V tap on models 16133, 16133-50, 16233, and 16214 optional. Must be specified at order placement.
  3. Special voltages, mounting, and lead out configurations are available. Consult factory for details.