Class 2 Transformers
Class 2 Transformers and SELV Low Voltage Control Transformers.
Class 2 or Class II control transformers represent one of the most common commercial transformer applications, and are found in a broad range of industrial, medical, and consumer applications. Class 2 transformers have unique characteristics to enhance safety. Most notably, low secondary voltage to reduce electrical shock hazard and low power to reduce fire hazard. The specific design requirements for Class 2 and Class 3 transformers are described in Underwriters Laboratories Standard UL 5085-1 and UL 5085-3 (formerly UL 1585) and CSA C22.2 No. 66.1 and C22.2 No. 66.3 (formerly CSA C22.2 No. 66). Class 2 circuits themselves are defined in the National Electrical Code, NFPA 70, Article 725. While there is no direct equivalent to Class 2 circuits abroad, EN 61558-1 (Safety of Power Transformers) and EN 61558-2-6 (Particular Requirements for Safety Isolating Transformers for General Use) have an analogue, Safety Isolating Transformers, which provide power to SELV (safety-extra-low-voltage) circuits.
The Foster Transformer Company offers a broad selection of standard Class 2 and SELV Safety Isolating Transformers from 5 VA through 100 VA. Our Low Voltage Class 2 Transformer series offer an economical solution with output voltages of 12 V, 24 V, and 24 VCT and capacities of 5 VA, 20 VA, and 50 VA. For more demanding and higher power applications our industry leading SURVIVOR™ and SURVIVOR CT™ series are excellent choices. Our SURVIVOR™ Class 2 transformers are available with output voltages of 24 V or 26.5 V and capacities of 40 VA, 50 VA, 75 VA, and 100 VA. Our SURVIVOR CT™ series add a center tapped output winding to provide 12 V and 24 V connections. All of Foster Transformer Company’s UL and C-UL Recognized Class 2 transformers are classified as Inherently Limited and require no additional external fusing or circuit protection.
Foster Transformer Company also offers a variety of UL Listed and C-UL Certified Class 2 transformers. Listed transformers are commonly used when a transformer will be field installed or not otherwise installed in a location which provides a protective enclosure. For customer’s seeking to export their equipment to the EU, our SELV Safety Isolating Transformers are an ideal solution. Incorporating all of the features of our SURVIVOR™ UL Recognized Class 2 transformers, our SELV Safety Isolating Transformers are Glow-Wire Compliant and certified to EN 61558-1, EN 61558-2-6, and EN 60335-1.
If you have questions, require additional information or would like pricing information, please contact us today.
Model | Input | Frequency | Output | Capacity | A | B | C | D | E | F |
---|---|---|---|---|---|---|---|---|---|---|
12652 | 120V | 50/60Hz | 24V | 50VA | 3 | 2 8/16 | 2 8/16 | 2 | 3 10/16 | |
12987 | 277V | 50/60Hz | 24V | 50VA | 3 | 2 8/16 | 2 8/16 | 2 | 3 10/16 | |
14694 | 120/208/240V | 50/60Hz | 24V | 50VA | 3-5/8 | 3-1/8 | 3-1/16 | 3-3/4 | 1-1/16 | 3-1/4 |
14695 | 220/380/415V | 50/60Hz | 24V | 50VA | 3-5/8 | 3-1/8 | 3-1/16 | 3-3/4 | 1-1/16 | 3-1/4 |
14696 | 208/240/480V | 50/60Hz | 24V | 50VA | 3-5/8 | 3-1/8 | 3-1/16 | 3-3/4 | 1-1/16 | 3-1/4 |
14762 | 240/480/575V | 50/60Hz | 24V | 50VA | 3-5/8 | 3-1/8 | 3-1/16 | 3-3/4 | 1-1/16 | 3-1/4 |
15299 | 115V | 50/60 Hz | 24VCT | 30VA | 2 13/16 | 3 4/16 | 2 3/16 | 2 | 3/16 | |
15335 | 240V | 50/60Hz | 24V | 50VA | 3 | 2 8/16 | 2 8/16 | 2 | 3 10/16 | |
15336 | 220V | 50/60Hz | 24V | 50VA | 3 | 2 8/16 | 2 8/16 | 2 | 3 10/16 | |
15341 | 200/230V | 60Hz | 24V | 75VA | 3 9/16 | 4 | 2 8/16 | 2 9/16 | 3/16 | |
15342 | 460V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 8/16 | 2 9/16 | 3/16 | |
15342 | 460V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 8/16 | 2 9/16 | 3/16 | |
15343 | 115V | 50/60Hz | 24V | 40VA | 2 13/16 | 3 4/16 | 2 3/16 | 1 15/16 | 3/16 | |
15344 | 200/230V | 50/60Hz | 24V | 40VA | 2 13/16 | 3 4/16 | 2 3/16 | 1 15/16 | 3/16 | |
15345 | 115/230V | 50/60Hz | 24V | 40VA | 2 13/16 | 3 4/16 | 2 3/16 | 1 15/16 | 3/16 | |
15346 | 115/230V | 50/60Hz | 24V | 50VA | 3 2/16 | 3 11/16 | 2 6/16 | 2 5/16 | 3/16 | |
15347 | 115/(200)/230V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15347 | 115/(200)/230V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15348 | 115V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 8/16 | 2 9/16 | 3/16 | |
15348 | 115V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 8/16 | 2 9/16 | 3/16 | |
15348-50 | 115V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15349 | 200/230V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15349 | 200/230V | 50/60Hz | 24V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15349-02 | 220/230/240V | 50/60Hz | 26.5V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15349-02 | 220/230/240V | 50/60Hz | 26.5V | 75VA | 3 9/16 | 4 | 2 12/16 | 2 9/16 | 3/16 | |
15694 | 115V | 50/60Hz | 24V | 50VA | 3 2/16 | 3 11/16 | 2 6/16 | 2 5/16 | 3/16 | |
15695 | 200/230V | 50/60Hz | 24V | 50VA | 3 2/16 | 3 11/16 | 2 6/16 | 2 5/16 | 3/16 | |
15696 | 115V | 50/60Hz | 24V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
15696 | 115V | 50/60Hz | 24V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
15697 | 115/(200)/230V | 50/60Hz | 24V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
15697 | 115/(200)/230V | 50/60Hz | 24V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
15698 | 200/230V | 50/60Hz | 24V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
15698 | 200/230V | 50/60Hz | 24V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
16019 | 115V | 50/60Hz | 24VCT | 50VA | 2-11/16 | 3-1/8 | 3-11/16 | 2-1/4 | 2-3/8 | 1-1/16 |
16020 | 115/230V | 50/60Hz | 24VCT | 50VA | 2-11/16 | 3-1/8 | 3-11/16 | 2-1/4 | 2-3/8 | 1-1/16 |
16021 | 200/230V | 50/60Hz | 24VCT | 50VA | 2-11/16 | 3-1/8 | 3-11/16 | 2-1/4 | 2-3/8 | 1-1/16 |
16025 | 115V | 50/60Hz | 26.5V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
16025 | 115V | 50/60Hz | 26.5V | 100VA | 2 8/16 | 3 | 2 12/16 | 2 13/16 | 13/64 | 10/16 |
16026 | 200/230V | 50/60Hz | 26.5V | 100VA | 2-1/2 | 3 | 2-3/4 | 2-13/16 | 13/64 | 5/8 |
16026 | 200/230V | 50/60Hz | 26.5V | 100VA | 2-1/2 | 3 | 2-3/4 | 2-13/16 | 13/64 | 5/8 |
16080 | 115V | 50/60Hz | 12V | 5VA | 1 5/8 | 1 1/3 | 1.29 | 1 3/16 | 0.35 | 0.85 |
16080 | 115/120 V | 50/60 Hz | 12V | 5 VA | 1 5/8 | 1 1/3 | 1.29 | 1 3/16 | 0.35 | 0.85 |
16081 | 115/230V | 50/60Hz | 12V | 5VA | 1-11/16 | 2 | 2-3/8 | 1-3/8 | 1-3/8 | 9/16 |
16081-PC | 115/230V | 50/60Hz | 12V | 5VA | 1 5/8 | 1 1/3 | 1.29 | 1 3/16 | 0.35 | 0.85 |
16082 | 200/230V | 50/60Hz | 12V | 5VA | 1-11/16 | 2 | 2-3/8 | 1-3/8 | 1-3/8 | 9/16 |
16082-PC | 200/230V | 50/60Hz | 12V | 5VA | 1 5/8 | 1 1/3 | 1.29 | 1 3/16 | 0.35 | 0.85 |
16083 | 115V | 50/60Hz | 24VCT | 5VA | 1-11/16 | 2 | 2-3/8 | 1-3/8 | 1-1/2 | 11/16 |
16083-PC | 115V | 50/60Hz | 12/24V | 5VA | 1 5/8 | 1 1/3 | 1.28 | 1 5/16 | 0.35 | 0.85 |
16084 | 115/230V | 50/60Hz | 24VCT | 5VA | 1-11/16 | 2 | 2-3/8 | 1-3/8 | 1-1/2 | 11/16 |
16084-PC | 115/230V | 50/60Hz | 12/24V | 5VA | 1 5/8 | 1 1/3 | 1.28 | 1 5/16 | 0.35 | 0.85 |