Class 2 Transformers

Class 2 Transformers and SELV Low Voltage Control Transformers.

Class 2 or Class II control transformers represent one of the most common commercial transformer applications, and are found in a broad range of industrial, medical, and consumer applications. Class 2 transformers have unique characteristics to enhance safety. Most notably, low secondary voltage to reduce electrical shock hazard and low power to reduce fire hazard. The specific design requirements for Class 2 and Class 3 transformers are described in Underwriters Laboratories Standard UL 5085-1 and UL 5085-3 (formerly UL 1585) and CSA C22.2 No. 66.1 and C22.2 No. 66.3 (formerly CSA C22.2 No. 66). Class 2 circuits themselves are defined in the National Electrical Code, NFPA 70, Article 725. While there is no direct equivalent to Class 2 circuits abroad, EN 61558-1 (Safety of Power Transformers) and EN 61558-2-6 (Particular Requirements for Safety Isolating Transformers for General Use) have an analogue, Safety Isolating Transformers, which provide power to SELV (safety-extra-low-voltage) circuits.

The Foster Transformer Company offers a broad selection of standard Class 2 and SELV Safety Isolating Transformers from 5 VA through 100 VA. Our Low Voltage Class 2 Transformer series offer an economical solution with output voltages of 12 V, 24 V, and 24 VCT and capacities of 5 VA, 20 VA, and 50 VA. For more demanding and higher power applications our industry leading SURVIVOR™ and SURVIVOR CT™ series are excellent choices. Our SURVIVOR™ Class 2 transformers are available with output voltages of 24 V or 26.5 V and capacities of 40 VA, 50 VA, 75 VA, and 100 VA. Our SURVIVOR CT™ series add a center tapped output winding to provide 12 V and 24 V connections. All of Foster Transformer Company’s UL and C-UL Recognized Class 2 transformers are classified as Inherently Limited and require no additional external fusing or circuit protection.

Foster Transformer Company also offers a variety of UL Listed and C-UL Certified Class 2 transformers. Listed transformers are commonly used when a transformer will be field installed or not otherwise installed in a location which provides a protective enclosure. For customer’s seeking to export their equipment to the EU, our SELV Safety Isolating Transformers are an ideal solution. Incorporating all of the features of our SURVIVOR™ UL Recognized Class 2 transformers, our SELV Safety Isolating Transformers are Glow-Wire Compliant and certified to EN 61558-1, EN 61558-2-6, and EN 60335-1.

If you have questions, require additional information or would like pricing information, please contact us today.

ModelInputFrequencyOutputCapacityABCDEF
12652120V50/60Hz24V50VA32 8/162 8/1623 10/16 
12987277V50/60Hz24V50VA32 8/162 8/1623 10/16 
14694120/208/240V50/60Hz24V50VA3-5/83-1/83-1/163-3/41-1/163-1/4
14695220/380/415V50/60Hz24V50VA3-5/83-1/83-1/163-3/41-1/163-1/4
14696208/240/480V50/60Hz24V50VA3-5/83-1/83-1/163-3/41-1/163-1/4
14762240/480/575V50/60Hz24V50VA3-5/83-1/83-1/163-3/41-1/163-1/4
15299115V50/60 Hz24VCT30VA2 13/163 4/162 3/162 3/16 
15335240V50/60Hz24V50VA32 8/162 8/1623 10/16 
15336220V50/60Hz24V50VA32 8/162 8/1623 10/16 
15341200/230V60Hz24V75VA3 9/1642 8/162 9/16 3/16 
15342460V50/60Hz24V75VA3 9/1642 8/162 9/16 3/16 
15342460V50/60Hz24V75VA3 9/1642 8/162 9/16 3/16 
15343115V50/60Hz24V40VA2 13/163 4/162 3/161 15/16 3/16 
15344200/230V50/60Hz24V40VA2 13/163 4/162 3/161 15/16 3/16 
15345115/230V50/60Hz24V40VA2 13/163 4/162 3/161 15/16 3/16 
15346115/230V50/60Hz24V50VA3 2/163 11/162 6/162 5/16 3/16 
15347115/(200)/230V50/60Hz24V75VA3 9/1642 12/162 9/16 3/16 
15347115/(200)/230V50/60Hz24V75VA3 9/1642 12/162 9/16 3/16 
15348115V50/60Hz24V75VA3 9/1642 8/162 9/16 3/16 
15348115V50/60Hz24V75VA3 9/1642 8/162 9/16 3/16 
15348-50115V50/60Hz24V75VA3 9/1642 12/162 9/16 3/16 
15349200/230V50/60Hz24V75VA3 9/1642 12/162 9/16 3/16 
15349200/230V50/60Hz24V75VA3 9/1642 12/162 9/16 3/16 
15349-02220/230/240V50/60Hz26.5V75VA3 9/1642 12/162 9/16 3/16 
15349-02220/230/240V50/60Hz26.5V75VA3 9/1642 12/162 9/16 3/16 
15694115V50/60Hz24V50VA3 2/163 11/162 6/162 5/16 3/16 
15695200/230V50/60Hz24V50VA3 2/163 11/162 6/162 5/16 3/16 
15696115V50/60Hz24V100VA2 8/1632 12/162 13/1613/6410/16
15696115V50/60Hz24V100VA2 8/1632 12/162 13/1613/6410/16
15697115/(200)/230V50/60Hz24V100VA2 8/1632 12/162 13/1613/6410/16
15697115/(200)/230V50/60Hz24V100VA2 8/1632 12/162 13/1613/6410/16
15698200/230V50/60Hz24V100VA2 8/1632 12/162 13/1613/6410/16
15698200/230V50/60Hz24V100VA2 8/1632 12/162 13/1613/6410/16
16019115V50/60Hz24VCT50VA2-11/163-1/83-11/162-1/42-3/81-1/16
16020115/230V50/60Hz24VCT50VA2-11/163-1/83-11/162-1/42-3/81-1/16
16021200/230V50/60Hz24VCT50VA2-11/163-1/83-11/162-1/42-3/81-1/16
16025115V50/60Hz26.5V100VA2 8/1632 12/162 13/1613/6410/16
16025115V50/60Hz26.5V100VA2 8/1632 12/162 13/1613/6410/16
16026200/230V50/60Hz26.5V100VA2-1/232-3/42-13/1613/645/8
16026200/230V50/60Hz26.5V100VA2-1/232-3/42-13/1613/645/8
16080115/120 V50/60 Hz12V5 VA1 5/81 1/31.291 3/160.350.85
16080115V50/60Hz12V5VA1 5/81 1/31.291 3/160.350.85
16081115/230V50/60Hz12V5VA1-11/1622-3/81-3/81-3/89/16
16081-PC115/230V50/60Hz12V5VA1 5/81 1/31.291 3/160.350.85
16082200/230V50/60Hz12V5VA1-11/1622-3/81-3/81-3/89/16
16082-PC200/230V50/60Hz12V5VA1 5/81 1/31.291 3/160.350.85
16083115V50/60Hz24VCT5VA1-11/1622-3/81-3/81-1/211/16
16083-PC115V50/60Hz12/24V5VA1 5/81 1/31.281 5/160.350.85
16084115/230V50/60Hz24VCT5VA1-11/1622-3/81-3/81-1/211/16
16084-PC115/230V50/60Hz12/24V5VA1 5/81 1/31.281 5/160.350.85
Displaying 50 of 101 models