SURVIVORTM CT Class 2 Transformers
|
Designed for use in HVAC, Appliance, Vending, Battery Charger and other applications requiring a Class 2 Control Transformer. All Designs are Inherently Limited as defined by UL 5085-3 (UL 1585).
-
UL / C-UL Recognized. UL File: E17029.
-
UL Recognized Class 130 (B) Insulation System.
-
Breakthrough Short Circuit & Overload Protection.
-
No External Fusing Required.
-
Can Withstand a Direct Short Circuit in Excess of 15 Days!
-
Lowers Warranty Costs, Improves Customer Satisfaction.
-
CE Compliant Designs Available. |
|

Download SURVIVOR CT Class 2 Transformers pdf
|
Buy Online! SURVIVOR CT Class 2 Transformers available for sale online. Need something slightly different or completely new? We customize! Contact us for more information.
SURVIVORTM CT Class 2 Transformer Specifications:

| Model: |
Input: |
Frequency: |
Output: |
Capacity: |
A |
B |
C |
D |
E |
F |
| 15299 |
115V |
50/60Hz |
24VCT |
30VA |
2-13/16 |
3-1/4 |
2-3/16 |
2 |
3/16 |
---- |
| 16134 |
115V |
60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-1/2 |
2-9/16 |
3/16 |
---- |
| 16134-50 |
115V |
50/60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16133 |
115(200)/230V |
60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-1/2 |
2-9/16 |
3/16 |
---- |
| 16133-50 |
115(200)/230V |
50/60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16131 |
200/230V |
60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-1/2 |
2-9/16 |
3/16 |
---- |
| 16135 |
200/230V |
50/60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16132 |
460V |
60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-1/2 |
2-9/16 |
3/16 |
---- |
| 16132-50 |
460V |
50/60Hz |
24VCT |
75VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16232 |
115V |
60Hz |
24VCT |
100VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16213 |
115V |
50/60Hz |
24VCT |
100VA |
2-1/2 |
3 |
2-3/4 |
2-13/16 |
13/64 |
5/8 |
| 16233 |
115(200)/230V |
60Hz |
24VCT |
100VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16214 |
115(200)/230V |
50/60Hz |
24VCT |
100VA |
2-1/2 |
3 |
2-3/4 |
2-13/16 |
13/64 |
5/8 |
| 16234 |
200/230V |
60Hz |
24VCT |
100VA |
3-9/16 |
4 |
2-3/4 |
2-9/16 |
3/16 |
---- |
| 16215 |
200/230V |
50/60Hz |
24VCT |
100VA |
2-1/2 |
3 |
2-3/4 |
2-13/16 |
13/64 |
5/8 |
Notes: 1. All part numbers are UL Recognized, C-UL Component Certified to UL 5085-3 (UL1585) / C.S.A. C22.2, Number 66.1. 2. 200 V tap on models 16133, 16133-50, 16233, and 16214 optional. Must be specified at order placement. 3. Special voltages, mounting, and lead out configurations are available. Consult factory for details.
|