current transformer, current transformers

Standard Transformers

  • Complywith UL 1283and EN 133200 Requirements.
  • UL 94 V0 Enclosure.
  • LowCost,Quick Installation.
  • LowLeakageCurrent.
  • Ideal for Retrofit Applications.

Applications:

  • Appliance
  • Motor Control
  • Medical
  • Lighting
  • Industrial
  • Recreational Vehicles

Compact EMI filter modules provide high levels of EMI suppression in a convenient, low cost package. Standard models incorporate 5.0 mH common mode inductors suitable for up to 6 amps.

Optional bypass capacitors provide increased differential mode noise rejection and optional MOVs provide protection against line transients.

Custom configurations and multiple stage filters are available by special order.

Standard Transformers:

    10 kHz 100 kHz 1.0 MHz 10 MHz 100 MHz
A-16015 Common Mode: -10.44dBm -10.44dBm -29.73dBm -24.51dBm -24.51dBm
  Differential Mode: -0.15 dBm -1.81dBm -1.81dBm -18.71dBm -8.04dBm
A-16039 Common Mode: -7.91 dBm -28.05 dBm -15.35 dBm -20.57 dBm -76.07 dBm
(100-120 V Line) Differential Mode: -1.35 dBm -15.35 dBm -43.76 dBm -20.57 dBm -47.20dBm
(100-120 V Line) Common Mode: -1.35 dBm -15.35 dBm -37.06 dBm -20.57 dBm -2.84 dBm
(200-240 V Line) Differential Mode: -7.91 dBm -15.35 dBm -43.76 dBm -20.57 dBm -47.20dBm

Insertion loss data provided are typical and are not intended to indicate actual in circuit performance. EMI testing should be conduted in end application to verify compliance.

<< BACK