Compact EMI filter modules provide high levels of EMI suppression in a convenient, low cost package. Standard models incorporate 5.0 mH common mode inductors suitable for up to 6 amps.
Optional bypass capacitors provide increased differential mode noise rejection and optional MOVs provide protection against line transients.
Custom configurations and multiple stage filters are available by special order.
Buy Online! EMI Filters available for sale online.
Need something slightly different or completely new? We customize! Contact us for more information.
Benefits
- Comply with UL 1283 and EN 133200 Requirements.
- UL 94 VO Enclosure.
- Low Cost, Quick Installation.
- Low Leakage Current.
- Ideal for Retrofit Applications.
Typical Insertion Loss
|


|
|
|
10 KHZ |
100 kHz |
1.0 MHz |
10 MHz |
100 MHz |
| A-16015 |
Common Mode:
Differential Mode:
|
-10.44dBm
-0.15dBm |
-29.73dBm
-1.81dBm |
-36.44dBm
-3.80dBm |
-24.51dBm
-18.71dBm |
-8.87dBm
-8.04dBm |
A-16039
(100-120 V Line) |
Common Mode:
Differential Mode:
|
-7.91dBm
-1.35dBm |
-28.05dBm
-15.35dBm |
-37.06dBm
-43.76dBm |
-20.57dBm
-76.07dBm |
-2.84dBm
-47.20dBm |
A-16040
(200-240 V Line) |
Common Mode:
Differential Mode:
|
-7.91dBm
-1.35dBm |
-28.05dBm
-15.35dBm |
-37.06dBm
-43.76dBm |
-20.57dBm
-76.07dBm |
-2.84dBm
-47.20dBm |
Insertion loss data provided are typical and are not intended to indicate actual in circuit performance. EMI testing should be conducted in end application to verify compliance.